EFRP-2402/CAGE - Etasis EFRP-2402/CAGE Chassis. EFRP-2402 Enclosure Simple Type: Chassis / Enclosure
Request Quote
For Price
- Part Number:
- EFRP-2402/CAGE
- Model Number:
- EFRP-2402
- Make:
- ETASIS
- Lead Time:
- Available
- Qty In Stock:
- Available
Etasis EFRP-2402/CAGE Chassis. EFRP-2402 Enclosure Simple Type: Chassis / Enclosure
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Active Power Factor Correction
- Available for Vertical and Horizontal Type
- Compact size Module Design
- Current Sharing on +5V, +3.3V & +12V
- Front panel LED to Indicate Power Status
- MTBF >100,000 Hours
- Over Current Protection
- Over Power Protection
- Over Voltage Protection
- Power Fault Alarm Signals
- Remote DC Sense on +5V and +3.3V
- Short Circuit Protection
- Universal Power Input
Specifications
- +12V1 VDC=Max Load Current: 25A
- +3.3 VDC=Max Load Current: 28A
- +5 VDC=Max Load Current: 30A
- +5 Vsb DC=Max Load Current: 2A
- -12 VDC=Max Load Current: 0.8A
- -5 VDC=Max Load Current: 0.3A
- 2. The +5, +3.3 and +12 Volt combine total output shall not exceed 380W 3: Noise bandwidth is from DC to 20 MHz.=Notes
- Agency Requirements=Harmonic: Meet EN61000-3-2 standards
- Cooling Fan: 40x40x20 mm
- Cross Regulation: ±10%
- Cross Regulation: ±10%
- Cross Regulation: ±5%
- Cross Regulation: ±5%
- Cross Regulation: ±5%
- Cross Regulation: ±5%
- Efficiency: 65% minimum, at full load
- EMI/RFI: CE, FCC class B and CISPR class B
- General Specifications (PS)=Input Range: 100 to 240 VAC, +/-10%
- Hold up Time: 20mS minimum, at full load
- Input (PS)=Input Voltage: 90-264VAC
- Input Current: 7A MAX=Input (PS)
- Input Frequency: 47-63Hz
- Line Regulation: ±1%
- Line Regulation: ±1%
- Line Regulation: ±1%
- Line Regulation: ±1%
- Line Regulation: ±1%
- Line Regulation: ±1%
- Load Regulation: ±10%
- Load Regulation: ±10%
- Load Regulation: ±5%
- Load Regulation: ±5%
- Load Regulation: ±5%
- Load Regulation: ±5%
- Min Load Current: 0A
- Min Load Current: 0A
- Min Load Current: 0A
- Min Load Current: 0A
- Min Load Current: 1A
- Min Load Current: 1A
- Operating Humidity: 20 to 90 %=General
- Operating Temperature: 0 to 50 degree
- Power Factor: 0.95 minimum
- Power Good: 100 to 500 ms, TTL compatible signal
- PSON (Remote ON/OFF): TTL compatible signal
- Ripple & Noise: 100mV=Output Voltage
- Ripple & Noise: 120mV=Output Voltage
- Ripple & Noise: 120mV=Output Voltage
- Ripple & Noise: 60mV=Output Voltage
- Ripple & Noise: 60mV=Output Voltage
- Ripple & Noise: 60mV=Output Voltage
- Safety: UL, cUL, CB, TUV=Agency Requirements & Regulations
Applications
- None Available
Aliases
- None Available