ETASIS EFRP-3300S/CAGE Enclosure. Enclosure for 500W+250W Output Power Simple Type: Chassis / Enclosure

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • Active Power Factor Correction
  • Compact size Module Design
  • Current Sharing on +5V, +3.3V & +12V
  • Front panel LED to Indicate Power Status
  • MTBF >100,000 Hours
  • Over Current Protection
  • Over Power Protection
  • Over Voltage Protection
  • Power Fault Alarm Signals
  • Quick Removable Application
  • Remote DC Sense on +5V and +3.3V
  • Short Circuit Protection
  • Universal Power Input

Specifications

    General
  • +12V1 VDC=Max Load Current: 34A
  • +3.3 VDC=Max Load Current: 40A
  • +5 VDC=Max Load Current: 50A
  • +5 Vsb DC=Max Load Current: 2A
  • -12 VDC=Max Load Current: 1A
  • -5 VDC=Max Load Current: 0.5A
  • Agency Requirements=Harmonic: Meet EN61000-3-2 standards
  • Cooling Fan: 40x40x28 mm (SANYO)
  • Cross Regulation: ±5%
  • Cross Regulation: ±5%
  • Cross Regulation: ±5%
  • Cross Regulation: ±5%
  • Cross Regulation: ±5%
  • Cross Regulation: ±5%
  • Efficiency: 65% minimum, at full load
  • EMI/RFI: CE, FCC class B and CISPR class B
  • General Specifications (PS)=Input Range: 100 to 240 VAC, +/-10%
  • Hold up Time: 20mS minimum, at full load
  • Input (PS)=Input Voltage: 100-240VAC
  • Input Current: 12-6A=Input (PS)
  • Input Frequency: 47-63Hz
  • Line Regulation: ±1%
  • Line Regulation: ±1%
  • Line Regulation: ±1%
  • Line Regulation: ±1%
  • Line Regulation: ±1%
  • Line Regulation: ±1%
  • Load Regulation: ±5%
  • Load Regulation: ±5%
  • Load Regulation: ±5%
  • Load Regulation: ±5%
  • Load Regulation: ±5%
  • Load Regulation: ±5%
  • Min Load Current: 0A
  • Min Load Current: 0A
  • Min Load Current: 0A
  • Min Load Current: 2A
  • Min Load Current: 2A
  • Min Load Current: 3A
  • Operating Humidity: 20 to 90 %=General
  • Operating Temperature: 0 to 50ºC
  • Power Factor: 0.95 minimum
  • Power Good: 100 to 500 ms, TTL compatible signal
  • PSON (Remote ON/OFF): TTL compatible signal
  • Ripple & Noise: 100mV=Output Voltage
  • Ripple & Noise: 120mV=Output Voltage
  • Ripple & Noise: 120mV=Output Voltage
  • Ripple & Noise: 60mV=Output Voltage
  • Ripple & Noise: 60mV=Output Voltage
  • Ripple & Noise: 70mV=Output Voltage
  • Safety: UL, cUL, CB, TUV,CCC=Agency Requirements & Regulations

 

Applications

  • None Available

Aliases